CME2 Q Plus (MEV)
Overview
The CME2 Q Plus is ideal for continuous extract of stale, damp and polluted air to the outside environment.
The combination of aesthetic smooth lines, unique tilted impeller and single level ports provides the ideal solution for hidden ceiling installation in flats and apartments.
The unit has a very large duty range over 116 l/s (418 m3/hr) at 200 Pa.
Looking for after sales support?
Features & Benefits
- High energy efficiency levels, via Electronically Commutated (EC) motor
- Very low power consumption/specific fan power
- Airflow up to 137 l/s (493 m3/h) at 100 Pa
- Compact – unit is small and low in profile, can be fitted in airing cupboards, cupboards or loft spaces
- Easy installation due to innovative sub-assembly and unique packaging design
- Optional two part installation
- Performs to high levels through rectangular ports; does away with need for round to rectangular adaptors, saving cost, reducing joints and installation time
- Optional adjustable humidity sensor (between 55% RH & 85% RH) triggers boost speed proportionally
- Duct ports on one level, lessening need for unnecessary bends in ducting, saving cost, reducing joints and installation time
- Ideal for central mechanical ventilation in refurbishment of single floor dwellings where there is only space for rectangular ducting
- Low unit noise
- Fully adjustable boost overrun timer 0-30 minutes
- Can accept either 204mm x 60mm (standard) or 110mm x 54mm ducting (using provided converter)
- Unit can be cleaned and serviced without disturbing ducting
- Original enclosure design with 204mm x 60mm spigots on one level, ideal for low profile ceiling mounting
- For use in conjunction with Titon trickle vents
- Available in volt free and switch live inputs
- Hidden fixings
- Quick and easy commissioning
- Demand control ventilation ready
- Wide duty range
- Patent applied
- Can be mounted on any plane
Compatible Products
Technical Information
Technical Information
Product Codes
TP325 – CME base only (First fix).
Volt free switch inputs
TP302A – CME 2 Q Plus (Full assembly).
TP302HA – CME 2 Q Plus, humidity sensor, (Full assembly).
TP303A – CME 2 Q Plus Fan assembly only, (Second fix).
TP303HA – CME 2 Q Plus Fan assembly only, humidity sensor (Second fix).
Switch live inputs
TP304HA – CME 2 Q Plus, humidity sensor (Full assembly).
TP305HA – CME 2 Q Plus Fan assembly only, humidity sensor (Second fix).
Standards
Conforms to requirements of UK statutory Building Regulations and Technical Standards for Ventilation and BRE 398.
SAP Appendix Q tested
Exceeds requirements of Building Regulations Approved Document L (England & Wales).
EU RoHS Directive compliant.
Conforms to requirements of EC council directives relating to Electromagnetic Compatibility and Electrical Safety:
2006/95/EC (LVD), 2004/108/EC (EMC) EN 60335-1:2002/A2:2006, EN 60335-2- 80:2003, A1:2004.CE Marked.
Other non-UK info available on request.
Specification
Dimensions (excluding ports): 355mm wide x 421mm long x 252mm high
Dimensions in mm.
Weight: 5kg
Finish: Light grey / dark grey
Materials;
Housing: Talc Filled Polypropylene
Guarantee period: 3 years (UK only)
Electrical: 230V ~ 50/60Hz, 3A fuse
Installation: To be installed accordance with the relevant and applicable building regulations.
Maintenance: See product manual.
Acoustics: Full acoustic data.
Performance
Exhaust terminal configuration*
|
Fan speed setting
|
Specific fan power (W/l/s)
|
Specific fan power
(W/l/s) |
2009
|
2012
|
||
Kitchen + 1 additional wet room
|
100% variable
|
0.20
|
0.20 |
Kitchen + 2 additional wet rooms
|
100% variable
|
0.17
|
0.17 |
Kitchen + 3 additional wet rooms
|
100% variable
|
0.18
|
0.19 |
Kitchen + 4 additional wet rooms
|
100% variable
|
0.2
|
0.21 |
Kitchen + 5 additional wet rooms
|
100% variable
|
0.23
|
0.25 |
Kitchen + 6 additional wet rooms
|
100% variable
|
0.28
|
0.29
|
Figures taken from the BRE Test Results.
*Number of wet rooms is based on SAP Q test criteria and does not correlate directly with regulatory performance requirements.
Test results available for use with 110 x 54mm ducting.
Performance Curve
Acoustic Data
Airflow
l/s |
% of
Max flow |
dB(A) @
3m Hemispherical |
dB(A) @ 3m Spherical
|
|
Induct
Inlet |
Casing
Breakout |
Casing
Breakout |
||
36 l/s
|
41%
|
20
|
23
|
20
|
57 l/s
|
65%
|
33
|
33
|
30
|
85 l/s
|
100%
|
42
|
41
|
38
|
Documentation
Resources
Manuals and Documentation
Product Manual - CME2 & CME2.1 Q Plus
URL for Product Manual - CME2 & CME2.1 Q Plus copied to clipboard.
Product Manual - CME2 Q Plus; Live Switching with Humidity Sensor
URL for Product Manual - CME2 Q Plus; Live Switching with Humidity Sensor copied to clipboard.
Product Manual - CME2 & CME2.1 Q Plus; First Fix Base
URL for Product Manual - CME2 & CME2.1 Q Plus; First Fix Base copied to clipboard.
Product Manual - Boxed Relay 5A (TP505)
URL for Product Manual - Boxed Relay 5A (TP505) copied to clipboard.
Catalogues
Ventilation Systems Catalogue
URL for Ventilation Systems Catalogue copied to clipboard.
Ventilation Product Overview Brochure
URL for Ventilation Product Overview Brochure copied to clipboard.
CME2 Q Plus - Catalogue Page
URL for CME2 Q Plus - Catalogue Page copied to clipboard.
CME - Sales Brochure
URL for CME - Sales Brochure copied to clipboard.
Social Housing Ventilation – MEV
URL for Social Housing Ventilation – MEV copied to clipboard.
Specifier Text
CME2 Q Plus - Specifiers Text (TP302A)
URL for CME2 Q Plus - Specifiers Text (TP302A) copied to clipboard.
CME2 Q Plus - Specifiers Text (TP302HA)
URL for CME2 Q Plus - Specifiers Text (TP302HA) copied to clipboard.
Acoustic Information
CME2 Q Plus - Acoustic Performance
URL for CME2 Q Plus - Acoustic Performance copied to clipboard.
User Guides
What is MEV?
URL for What is MEV? copied to clipboard.
CME2 Q Plus - User Guide
URL for CME2 Q Plus - User Guide copied to clipboard.
CME2 Q Plus - Spares Matrix
URL for CME2 Q Plus - Spares Matrix copied to clipboard.
NHBC Standards 2024 - Chapter 8.4.1
URL for NHBC Standards 2024 - Chapter 8.4.1 copied to clipboard.
MVHR/MEV Running Costs
URL for MVHR/MEV Running Costs copied to clipboard.
Fault Finding
CME2/2.1 Q Plus - Fault Finding (Units With Live Switching)
URL for CME2/2.1 Q Plus - Fault Finding (Units With Live Switching) copied to clipboard.
CME1 & CME2/2.1 Q Plus - Fault Finding Document (Volt Free Switching)
URL for CME1 & CME2/2.1 Q Plus - Fault Finding Document (Volt Free Switching) copied to clipboard.
Calculators
Part F Calculator (UK only)
URL for Part F Calculator (UK only) copied to clipboard.
Test Results
Product Characteristics Database (PCDB) – CME2 Q Plus A Test Results
URL for Product Characteristics Database (PCDB) – CME2 Q Plus A Test Results copied to clipboard.
Product Characteristics Database (PCDB) – CME2 Q Plus HA Test Results
URL for Product Characteristics Database (PCDB) – CME2 Q Plus HA Test Results copied to clipboard.
Quote and Order Form
Request for Information (R.F.I.) Form
URL for Request for Information (R.F.I.) Form copied to clipboard.
Product Fiches
Product Fiche CME2 Q Plus (TP302A)
URL for Product Fiche CME2 Q Plus (TP302A) copied to clipboard.
Product Fiche CME2 Q Plus (TP302HA)
URL for Product Fiche CME2 Q Plus (TP302HA) copied to clipboard.
Product Fiche CME2 Q Plus (TP303HA)
URL for Product Fiche CME2 Q Plus (TP303HA) copied to clipboard.
BIM Models
CME2 Q Plus - BIM Model
URL for CME2 Q Plus - BIM Model copied to clipboard.
Videos
Video: Product Overview - MEV, CME Q Plus
URL for Video: Product Overview - MEV, CME Q Plus copied to clipboard.
CE Certificate of Conformity
CME2 Q Plus HA Live Switch Humidity & 2nd Fix - Certificate of Conformity (TP304HA-010 & TP305HA-010)
URL for CME2 Q Plus HA Live Switch Humidity & 2nd Fix - Certificate of Conformity (TP304HA-010 & TP305HA-010) copied to clipboard.
CME2 Q Plus HA Humidity & 2nd Fix Unit - Certificate of Conformity (TP302HA-010 & TP303HA-010)
URL for CME2 Q Plus HA Humidity & 2nd Fix Unit - Certificate of Conformity (TP302HA-010 & TP303HA-010) copied to clipboard.
CME2 Q Plus A & 2nd Fix Unit- Certificate of Conformity (TP302A-010 & TP303A-010)
URL for CME2 Q Plus A & 2nd Fix Unit- Certificate of Conformity (TP302A-010 & TP303A-010) copied to clipboard.
UKCA Certificate of Conformity
CME2 Q Plus HA Live Switch Humidity & 2nd Fix - UKCA Certificate of Conformity (TP304HA-010)
URL for CME2 Q Plus HA Live Switch Humidity & 2nd Fix - UKCA Certificate of Conformity (TP304HA-010) copied to clipboard.
CME2 Q Plus A & 2nd Fix Unit - UKCA Certificate of Conformity (TP302A-010)
URL for CME2 Q Plus A & 2nd Fix Unit - UKCA Certificate of Conformity (TP302A-010) copied to clipboard.
CME2 Q Plus HA Humidity & 2nd Fix Unit - UKCA Certificate of Conformity (TP302HA-010)
URL for CME2 Q Plus HA Humidity & 2nd Fix Unit - UKCA Certificate of Conformity (TP302HA-010) copied to clipboard.