aurastat® V & VT

For use with Titon HRV Q Plus Range gives enhanced commissioning capabilities
HRV Q PLUS CONTROLLER

Overview

aurastat® is a low voltage, intelligent controller with LCD display for commissioning and monitoring a Titon TP***B HRV unit. It is wired to the unit but situated remotely.

aurastat® V also has a commissioning only option. Once programmed, the HRV unit runs without the need for the controller

Features & Benefits

  • User friendly interface showing system status, fan speeds/air temperature and more
  • Boost alert triggers a warning message when the HRV has been left in boost
  • Grants the occupant accessibility and control
  • PIN protected menu structure for commissioning
  • Low power consumption
  • Individual supply/extract fan speed settings
  • Separate kitchen and wet room boost function settings
  • Demand control features via 2 x 0-10V DC proportional sensor inputs (power supplied from main PCB, RH, CO2, Air quality and temperature)
  • Fully automatic summer bypass
  • Intelligent frost protection
  • Boost delay
  • Boost inhibit within selected time zones
  • Running hours recorder
  • Internal MVHR humidity sensor setpoint
  • Fully adjustable SUMMERboost® speed (linked to automatic bypass)
  • Programmable timer option Mains voltage or volt free boost switching

Technical Information

Technical Information

Description

aurastat® is controlled via buttons that configure and monitor the HRV using five different menu systems:

  • Monitor and control ‘Run’ menu
  • User set up ‘SETUP1’
  • Service and set up ‘SETUP2’
  • Commissioning and installation ‘SETUP3’
  • Reset ‘RESET4’

The display is a back lit 90mm LCD screen which combines a mixture of icons, text and figures aurastat® can be used to set and control a number of features including:

  • Boost alert timer
  • Summer Mode, Summer Bypass and SUMMERboost® settings
  • Duct heater settings
  • Room sensor set points
  • Internal humidity settings
  • Continuous, boost and set back speeds

The home occupant has access to set a number of features themselves, such as:

  • 24-hour clock
  • Day of week display
  • Back light brightness
  • Boost overrun timer
  • Boost delay timer
  • Boost inhibit times
  • Internal humidity sensor set point
  • Filter change alert interval and reset

aurastat® VT has the additional features of programmable weekly timers that are used to setback or boost the ventilation rates at specific times.

aurastat® is used to set up and control specific versions of Titon’s HRV units.

Titon aurastat® HRV controller for commissioning and monitoring a Titon HRV Q Plus unit.

Product Codes

aurastat® V – TP526Buy online
aurastat® VT – TP534

Standards

Conforms to requirements of EC council directives relating to Electromagnetic Compatibility and Electrical Safety: 2006/95/EC (LVD), 2004/108/EC (EMC) EN 60335-1:2002/A2:2006, EN 60335-2-80:2003/A1:2004
CE marked
Patented and Registered design

Specification

Dimensions: 106mm wide x 141mm high x 25mm deep
Weight: 185g
Finish: High gloss finish
Materials: ABS
Guarantee period: 3 years (UK only)
Electrical: 12V DC

Drawing and Dimensions

Dimensions in mm.

Documentation

Resources

Manuals and Documentation

Catalogues

Ventilation Systems Catalogue

21.01 MB (English)
Download

URL for Ventilation Systems Catalogue copied to clipboard.

aurastat® - Catalogue Page

374.14 KB (English)
Download

URL for aurastat® - Catalogue Page copied to clipboard.

User Guides

aurastat® - Defaults Guide

147.38 KB (English)
Download

URL for aurastat® - Defaults Guide copied to clipboard.

Certificate of Conformity

aurastat® VT – Certificate of Conformity (TP534)

264.35 KB (English)
Download

URL for aurastat® VT – Certificate of Conformity (TP534) copied to clipboard.

aurastat® V – Certificate of Conformity (TP526-BEL)

276.5 KB (English)
Download

URL for aurastat® V – Certificate of Conformity (TP526-BEL) copied to clipboard.

aurastat® V – Certificate of Conformity (TP526)

276.5 KB (English)
Download

URL for aurastat® V – Certificate of Conformity (TP526) copied to clipboard.

aurastat® VT – Certificate of Conformity (TP534-EST)

264.35 KB (English)
Download

URL for aurastat® VT – Certificate of Conformity (TP534-EST) copied to clipboard.

aurastat® VT – Certificate of Conformity (TP534-BEL)

264.35 KB (English)
Download

URL for aurastat® VT – Certificate of Conformity (TP534-BEL) copied to clipboard.

aurastat® VT – Certificate of Conformity (TP534-LTU)

264.35 KB (English)
Download

URL for aurastat® VT – Certificate of Conformity (TP534-LTU) copied to clipboard.

aurastat® VT – Certificate of Conformity (TP534-ROU)

264.35 KB (English)
Download

URL for aurastat® VT – Certificate of Conformity (TP534-ROU) copied to clipboard.

aurastat® VT – Certificate of Conformity (TP534-SVN)

264.35 KB (English)
Download

URL for aurastat® VT – Certificate of Conformity (TP534-SVN) copied to clipboard.

Woman working at computer

Contact one of our experts

Whatever your query, please get in touch.