Skip to content

HRV10M Q Plus

Mechanical Ventilation with Heat Recovery unit (MVHR)
LARGE SIZED DWELLINGS
Buy

Overview

The HRV10M Q Plus continuously running whole house ventilation unit with heat recovery has been specifically designed to give improved performance over older models, in line with new build design requirements.

Combining of extremely low power consumption and a highly efficient heat exchanger specifically designed to enhance SAP performance via Appendix Q and can be incorporated into larger apartments or dwellings.

The Eco versions offer a 100% airflow diverting Summer Bypass, recognised and listed in the UK Product Characteristics Database. They also include intelligent humidity options and can be fitted with the auralite® status indicator, aura-t™ controller (HMB or B Models) or the auramode® and aurastat® controllers (B models only).

Features & Benefits

  • Extremely low Specific Fan Power of 0.48 W/l/s
  • Highly efficient heat exchanger; up to 92%
  • Airlow up to 116 l/s (419m3/h) at 100 Pa
  • Lightweight EPP construction giving high levels of thermal insulation
  • Accepts 150mm or 125mm diameter ducting
  • Independent fan adjustment
  • Intelligent frost protection, stepped reduction of supply air rates prevents HRV unit from freezing
  • Setback facility to reduce ventilation where local regulations allow
  • Fully adjustable boost overrun timer 0-60 minutes; can be used with non-latching (momentary) switches to prevent unit from being accidentally left in boost mode
  • Intelligent controller, quick and easy to commission
  • EPP moulded 150-125mm low resistance insulated port adaptors included as standard
  • Volt free switching control
  • Pleated ISO Coarse 65% (G4) filters as standard. ISO ePM1 55% (F7) on request (Standard unit only)
  • EPP cased version available (HRV10 Q Plus)
  • Quick fix mounting bracket
  • On board aura-tTM capabilities
  • Patented features
  • Effective in reducing pollutants in the home and improving Indoor Air Quality (IAQ), therefore reducing the risk of Toxic Home Syndrome

Basic version;

  • Summer Mode

Eco versions;

  • Intelligent Summer Bypass & humidity controls
  • SUMMERboost® facility

Eco HMB Models;

  • Compatible with auralite® status (TP518) indicator and aura-tTM controller

Eco B Models;

  • Compatible with aura range; aurastat®, auramode®, aura-t™ and auralite® (TP519) controllers
  • Duct heater control (requires independent power supply)
  • BMS compatible via RS485

Compatible Products

aurastat® V & VT

For use with Titon HRV Q Plus Range gives enhanced commissioning capabilities

Technical Information

Technical Information

Product Codes

HRV10M Q Plus
TP441A – Energy Rating A

HRV10M Q Plus HMB Eco auralite® & aura-tTM ready –
TP441HMB – Energy Rating A

HRV10M Q Plus B Eco-aura controls ready –
TP481B – Energy Rating A+

HRV10M Q Plus B Eco-aura controls Cold Climate ready –
TP481BC – Energy Rating A+

Filters:
XP44022/099 – ISO Coarse 65% (G4) filter set fitted as standard.

Filters (Eco versions):
XP44023/099 – ISO Coarse 65% (G4) bypass filter set fitted as standard.
XP46223/099 – ISO Coarse 65% (G4)/ISO ePM1 55% (F7) filters available on request.

Standards

Conforms to requirements of UK statutory Building Regulations and Technical Standards for Ventilation and BRE 398.
SAP Appendix Q tested
Exceeds requirements of Building Regulations Approved Document L (England & Wales).
EU RoHS Directive compliant.
Conforms to requirements of EC council directives relating to Electromagnetic Compatibility and Electrical Safety:
2006/95/EC (LVD), 2004/108/EC (EMC), EN 60335-1:2002/A2:2006, EN 60335-2- 80:2003/A1:2004.
CE Marked.

Specification

Dimensions: 800mm wide x 675mm high (excluding ports) x 470mm deep (481mm with mounting bracket).


Weight: 37kg.
Finish – White Paint.

Materials:
Housing – Zintec sheet steel, powder coated. Internal expanded polypropylene (EPP), Heat Exchanger – Polystyrene, Internal Insulation – Closed cell foamed, Nitrile rubber, class ‘O’ fire rating, Standard filters: Grade ISO Coarse 60% (G4) pleated panel filters.
Guarantee period: 3 years (UK only).
Electrical: 230V ~ 50/60Hz, 3A fuse.
Installation: Install in accordance with regulatory requirements, such as the Domestic Ventilation Compliance Guide (England & Wales) and the Residential Ventilation Association recommendations.
Maintenance: Service and filter clean/replacement subject to local environment – see product manual.
AcousticsFull acoustic data.

Performance

Exhaust terminal configuration*
Fan speed setting
Specific fan power (W/l/s)
Heat exchange efficiency (%)
Kitchen + 1 additional wet room
100% variable
0.52 92
Kitchen + 2 additional wet room
100% variable
0.48 92
Kitchen + 3 additional wet room
100% variable
0.51 92
Kitchen + 4 additional wet room
100% variable
0.55 91
Kitchen + 5 additional wet room
100% variable
0.62 91
Kitchen + 6 additional wet room
100% variable
0.74 90
Kitchen + 7 additional wet room
100% variable
0.87 89

Figures taken from the BRE Test Results.
*Number of wet rooms is based on SAP Q test criteria and does not correlate directly with regulatory performance requirements.

Performance Curve

All acoustic data is third party tested at Sound Research Laboratories (SRL) Ltd.

Acoustic Data

Product
% of Max flow
Airflow
dB(A) @ 3m Hemispherical
dB(A) @ 3m Spherical
Induct Inlet
Induct Outlet
Casing Breakout
Casing Breakout
HRV10M Q Plus Eco
41%
44l/s @ 22Pa
27
38
27
20
69%
75l/s @ 51Pa
36
48
37
30
100%
108l/s @ 100Pa
43
57
51
43

For full frequency acoustic data at various speeds please see www.titon.co.uk. All acoustic data is third party tested at Sound Research Laboratories (SRL) Ltd.

Documentation

Resources

URL

How to identify which HRV (MVHR) you have

(English)
Visit URL

URL for How to identify which HRV (MVHR) you have copied to clipboard.

HRV Filters - Buy online

(English)
Visit URL

URL for HRV Filters - Buy online copied to clipboard.

Manuals and Documentation

Product Manual - auramode Constant Flow Unit Controller BAR units

8.38 MB (English)
Download

URL for Product Manual - auramode Constant Flow Unit Controller BAR units copied to clipboard.

Product Manual - auralite® (TP519)

340.24 KB (English)
Download

URL for Product Manual - auralite® (TP519) copied to clipboard.

Product Manual - aura-t™ HMB Model

3.83 MB (English)
Download

URL for Product Manual - aura-t™ HMB Model copied to clipboard.

Product Manual - aura-t™ B Model GBR

4.95 MB (English)
Download

URL for Product Manual - aura-t™ B Model GBR copied to clipboard.

Product Manual - Boxed Relay 5A (TP505)

575.63 KB (English)
Download

URL for Product Manual - Boxed Relay 5A (TP505) copied to clipboard.

Manuals and Documentation (Obsolete)

Product Manual - HRV10 & 10M Q Plus (TP480B & TP481B) - (Obsolete)

2.59 MB (Français)
Download

URL for Product Manual - HRV10 & 10M Q Plus (TP480B & TP481B) - (Obsolete) copied to clipboard.

Product Manual - HRV10 & 10M Q Plus (TP440HMB & TP441HMB) - (Obsolete)

2.65 MB (English)
Download

URL for Product Manual - HRV10 & 10M Q Plus (TP440HMB & TP441HMB) - (Obsolete) copied to clipboard.

Product Manual - HRV10 & 10M Q Plus (TP440MB & TP441MB) - (Obsolete)

3.25 MB (English)
Download

URL for Product Manual - HRV10 & 10M Q Plus (TP440MB & TP441MB) - (Obsolete) copied to clipboard.

Product Manual - HRV10 & 10M Q Plus (TP440A, TP440ABD, TP440ABS) - (Obsolete)

5.06 MB (English)
Download

URL for Product Manual - HRV10 & 10M Q Plus (TP440A, TP440ABD, TP440ABS) - (Obsolete) copied to clipboard.

Test Results

Product Characteristics Database (PCDB) – HRV10 Q Plus ECO Test Results

(English)
Visit URL

URL for Product Characteristics Database (PCDB) – HRV10 Q Plus ECO Test Results copied to clipboard.

Specifier Text

HRV10M Q Plus - Specifiers Text (TP481B)

199.17 KB (English)
Download

URL for HRV10M Q Plus - Specifiers Text (TP481B) copied to clipboard.

HRV10M Q Plus - Specifiers Text (TP441HMB)

198.14 KB (English)
Download

URL for HRV10M Q Plus - Specifiers Text (TP441HMB) copied to clipboard.

HRV10M Q Plus - Specifiers Text (TP441A)

196.61 KB (English)
Download

URL for HRV10M Q Plus - Specifiers Text (TP441A) copied to clipboard.

Catalogues

MVHR Overview Brochure (UK Version)

2.38 MB (English)
Download

URL for MVHR Overview Brochure (UK Version) copied to clipboard.

MVHR Overview Brochure (Export Version)

1.79 MB (English)
Download

URL for MVHR Overview Brochure (Export Version) copied to clipboard.

HRV10 Q Plus - Catalogue Page

1.33 MB (English)
Download

URL for HRV10 Q Plus - Catalogue Page copied to clipboard.

HRV - Sales Brochure

1.96 MB (English)
Download

URL for HRV - Sales Brochure copied to clipboard.

aura-t™ B – Catalogue Page

264.57 KB (English)
Download

URL for aura-t™ B – Catalogue Page copied to clipboard.

aura-t™ HMB - Catalogue Page

263.78 KB (English)
Download

URL for aura-t™ HMB - Catalogue Page copied to clipboard.

aurastat® - Catalogue Page

312.76 KB (English)
Download

URL for aurastat® - Catalogue Page copied to clipboard.

auralite® - Catalogue Page

269.01 KB (English)
Download

URL for auralite® - Catalogue Page copied to clipboard.

auramode® - Catalogue Page

329.73 KB (English)
Download

URL for auramode® - Catalogue Page copied to clipboard.

MVHR/HRV Drain Conversion - Datasheet

334.56 KB (English)
Download

URL for MVHR/HRV Drain Conversion - Datasheet copied to clipboard.

Acoustic Information

HRV10M Q Plus - Acoustic Results

559.05 KB (English)
Download

URL for HRV10M Q Plus - Acoustic Results copied to clipboard.

Sound Attenuating Ventilation

385.72 KB (English)
Download

URL for Sound Attenuating Ventilation copied to clipboard.

Certificate of Conformity

HRV10M Q Plus - Certificate of Conformity (TP481B-SVN)

311.52 KB (English)
Download

URL for HRV10M Q Plus - Certificate of Conformity (TP481B-SVN) copied to clipboard.

HRV10M Q Plus - Certificate of Conformity (TP481B-544)

311.52 KB (English)
Download

URL for HRV10M Q Plus - Certificate of Conformity (TP481B-544) copied to clipboard.

HRV10M Q Plus - Certificate of Conformity (TP441HMB-BEL)

311.51 KB (English)
Download

URL for HRV10M Q Plus - Certificate of Conformity (TP441HMB-BEL) copied to clipboard.

HRV10M Q Plus - Certificate of Conformity (TP441HMB-544-T)

311.52 KB (English)
Download

URL for HRV10M Q Plus - Certificate of Conformity (TP441HMB-544-T) copied to clipboard.

HRV10M Q Plus - Certificate of Conformity (TP441HMB-544)

311.5 KB (English)
Download

URL for HRV10M Q Plus - Certificate of Conformity (TP441HMB-544) copied to clipboard.

HRV10M Q Plus - Certificate of Conformity (TP441A-544)

311.5 KB (English)
Download

URL for HRV10M Q Plus - Certificate of Conformity (TP441A-544) copied to clipboard.

HVR10M Q Plus – Certificate of Conformity (TP481B)

319.39 KB (English)
Download

URL for HVR10M Q Plus – Certificate of Conformity (TP481B) copied to clipboard.

HVR10M Q Plus – Certificate of Conformity (TP441HMB)

319.38 KB (English)
Download

URL for HVR10M Q Plus – Certificate of Conformity (TP441HMB) copied to clipboard.

HVR10M Q Plus – Certificate of Conformity (TP441A)

319.39 KB (English)
Download

URL for HVR10M Q Plus – Certificate of Conformity (TP441A) copied to clipboard.

User Guides

HRV - Spares Matrix

340.54 KB (English)
Download

URL for HRV - Spares Matrix copied to clipboard.

HRV Q Plus - Fault Finding (MB)

1.94 MB (English)
Download

URL for HRV Q Plus - Fault Finding (MB) copied to clipboard.

HRV Q Plus - Fault Finding (ABS)

1.74 MB (English)
Download

URL for HRV Q Plus - Fault Finding (ABS) copied to clipboard.

HRV Q Plus - Fault Finding (A)

934.79 KB (English)
Download

URL for HRV Q Plus - Fault Finding (A) copied to clipboard.

HRV Q Plus - Fault Finding (ABD)

1.63 MB (English)
Download

URL for HRV Q Plus - Fault Finding (ABD) copied to clipboard.

HRV Q Plus - Fault Finding (HMB)

2.08 MB (English)
Download

URL for HRV Q Plus - Fault Finding (HMB) copied to clipboard.

HRV Q Plus - Port Configurations (Vertical Units)

2.19 MB (English)
Download

URL for HRV Q Plus - Port Configurations (Vertical Units) copied to clipboard.

HRV Q Plus - User Guide

835.61 KB (English)
Download

URL for HRV Q Plus - User Guide copied to clipboard.

aurastat® - Defaults Guide

147.38 KB (English)
Download

URL for aurastat® - Defaults Guide copied to clipboard.

Fitting Instructions - HMB aura-t Upgrade Kit

1.06 MB (English)
Download

URL for Fitting Instructions - HMB aura-t Upgrade Kit copied to clipboard.

Product Fiches

BIM Models

MVHR Vertical (RH) - BIM Model

451.37 KB (English)
Download

URL for MVHR Vertical (RH) - BIM Model copied to clipboard.

MVHR Vertical (LH) - BIM Model

454.45 KB (English)
Download

URL for MVHR Vertical (LH) - BIM Model copied to clipboard.

Videos

Video - How to change a filter (HRV)

(English)
Visit URL

URL for Video - How to change a filter (HRV) copied to clipboard.

Similar Products

Similar Products

Woman working at computer

Contact one of our experts

Whatever your query, please get in touch.