Skip to content

HRV4 Q Plus

Mechanical Ventilation with Heat Recovery unit (MVHR)
MEDIUM TO LARGE SIZED DWELLINGS

Overview

Introducing the new HRV4 Q Plus: a powerful yet compact, continuously running whole-house ventilation unit with heat recovery. It is suitable for larger dwellings and has been independently tested by the BRE. The HRV4 Q Plus delivers cutting-edge performance usually only associated with much larger and more expensive products.

The combination of very low power consumption and a highly efficient heat exchanger is specifically designed to enhance SAP performance via Appendix Q, yet small enough to be easily incorporated into medium sized dwellings.

Recognised and listed in the UK Product Characteristics Database and includes intelligent humidity options through controller options.

Looking for after sales support?

Features & Benefits

  • Extremely low Specific Fan Power; down to 0.38 W/l/s
  • Highly efficient heat exchanger; up to 91%
  • Airflow up to 123 l/s (443 m3/h) at 100 Pa
  • Intelligent controller, quick and easy to commission
  • Fully adjustable boost overrun timer 0-60 minutes; use with non-latching (momentary) switches to prevent unit from being accidentally left in boost mode
  • Accepts 150mm and 160mm diameter ducting, no adaptors required
  • Intelligent frost protection (B2 and HMB), stepped reduction of supply air rates prevents HRV unit from freezing (B2 model only)
  • Setback facility to reduce ventilation where local regulations allow
  • ISO Coarse 85% (G4) filters as standard
  • Quick fix mounting bracket
  • IP32 rating
  • Patented
  • Independent fan adjustment
  • Effective in reducing pollutants in the home and improving Indoor Air Quality (IAQ), therefore reducing
  • Intelligent Summer Bypass & humidity controls
  • SUMMERboost® facility

Technical Information

Technical Information

Product Codes and Specific Features

Eco HMB Models:

  • aura-t™ HMB controller available as standalone only
  • Fitted with removable filter covers on the front panel
Product Model Product Code Energy Rating
HRV4 Q Plus Eco HMB aura-t™ ready
Fitted with removable filter covers on the front panel
TP421HMB/544
(left hand config)
Energy Rating A
TP421HMB/RH
(right hand config)

Eco B2 Models:

  • aura-t™ B2 onboard as standard (WiFi option available not fitted as standard)
  • Front panel; drop down filter flap panel or removable filter covers option available
  • On site configured to either a LH or RH
  • Full MODBUS connectivity
  • BMS compatible via RS485 (subject to limitations, additional software requirements and specification with any order)
  • Low voltage switching (x 3) and live switch (x 2)
  • 4 x 0-10v proportional inputs for local demand control room sensors
  • Duct Pre-heater control (requires independent power supply)
Product Model Product Code Energy Rating
HRV4 Q Plus B2 aura-t™ control
(LH/RH on site configuration)*
TP431B2/LR-T*
(left hand config)
Energy Rating A+
HRV4 Q Plus B2 aura-t™ control
(LH/RH on site configuration)*
TP431B2F/LR-T*
(left hand config)
Energy Rating A+

*Standard supply always LH

Filters:
ISO Coarse 85% (G4) filters fitted as standard.

Standards

Conforms to requirements of UK statutory Building Regulations and Technical Standards for Ventilation and BRE 398.
SAP Appendix Q tested.
Exceeds requirements of Building Regulations Approved Document L (England & Wales).
EU RoHS Directive compliant.
Conforms to requirements of EC council directives relating to Electromagnetic Compatibility and Electrical Safety:
2006/95/EC (LVD), 2004/108/EC (EMC). EN 60335-1:2002/A2:2006, EN 60335-2- 80:2003/A1:2004.
CE and UKCA marked.

Specification

Dimensions: 600mm wide x 602mm high (excluding ports) x 477mm deep (487mm with mounting bracket)


Weight: 28.5kg.
Finish: White Paint (RAL9016 Semi-gloss Traffic White).

Materials;
Housing: Zintec sheet steel housing, powder coated white.
Internals: Expanded polypropylene (EPP).
Heat exchanger: Made from high quality PET (Polyethylene terephthalate) materials.
Internal insulation: Closed cell foamed Nitrile rubber, class ‘O’ fire rating.
Standard filters: Grade ISO Coarse 85% (G4) synthetic filters.
Guarantee period: 3 years (UK only).
Electrical: 230V ~ 50/60Hz, 3A fuse.
Installation: To be installed accordance with the relevant and applicable building regulations.
Maintenance: Service and filter replacement subject to local environment – see product manual.
Acoustics
: Full acoustic data.

Performance

Exhaust terminal configuration*
Fan speed setting
Specific fan power (W/l/s)
Heat exchange efficiency (%)
Specific fan power (W/l/s)
Heat exchange efficiency (%)
Specific fan power (W/l/s)
Heat exchange efficiency (%)
2009
2012
10
Kitchen + 1 additional wet room
100% variable
0.41 91% 0.42 91% 0.42 91%
Kitchen + 2 additional wet rooms
100% variable
0.38 91% 0.43 90% 0.43 90%
Kitchen + 3 additional wet rooms
100% variable
0.4 90% 0.5 89% 0.5 89%
Kitchen + 4 additional wet rooms
100% variable
0.45 89% 0.6 88% 0.6 88%
Kitchen + 5 additional wet rooms
100% variable
0.51 89% 0.73 87% 0.73 87%
Kitchen + 6 additional wet rooms
100% variable
0.58 88% 0.9 86% 0.9 86%
Kitchen + 7 additional wet rooms
100% variable
0.7 87% 1.08 86% 1.08 86%

Figures taken from the BRE Test Results.
*Number of wet rooms is based on SAP Q test criteria and does not correlate directly with regulatory performance requirements.

Performance Curve

*@FID (0 Pa)
All units offer 100% variable speed control.

Acoustic Data

Product
% of Max flow
Airflow
dB(A) @ 3m Hemispherical
dB(A) @ 3m Spherical
Induct Inlet
Induct Outlet
Casing Breakout
Casing Breakout
HRV4 Q Plus Eco
41% 47.9l/s  @ 15Pa 29 37 21 18
65% 80.4l/s  @  41Pa 38 50 31 28
100% 123.1l/s  @  100Pa 46 58 41 38

All acoustic data is third party tested at Sound Research Laboratories (SRL) Ltd.

Documentation

Resources

Manuals and Documentation

Product Manual – HRV (HMB Models)

6.09 MB (English)
Download

URL for Product Manual – HRV (HMB Models) copied to clipboard.

Product Manual – HRV (B2 Models)

12.66 MB (English)
Download

URL for Product Manual – HRV (B2 Models) copied to clipboard.

MVHR/HRV Drain Conversion - Datasheet

334.56 KB (English)
Download

URL for MVHR/HRV Drain Conversion - Datasheet copied to clipboard.

Catalogues

Ventilation Product Overview Brochure

3.81 MB (English)
Download

URL for Ventilation Product Overview Brochure copied to clipboard.

MVHR - Overview Brochure (Export Version)

1.34 MB (English)
Download

URL for MVHR - Overview Brochure (Export Version) copied to clipboard.

HRV4 Q Plus – Catalogue Page

472.22 KB (English)
Download

URL for HRV4 Q Plus – Catalogue Page copied to clipboard.

Acoustic Information

HRV4 Q Plus - Acoustic Performance

1.05 MB (English)
Download

URL for HRV4 Q Plus - Acoustic Performance copied to clipboard.

User Guides

What is MVHR?

(English)
Visit URL

URL for What is MVHR? copied to clipboard.

Top 10 Install Problems - Guide

2.65 MB (English)
Download

URL for Top 10 Install Problems - Guide copied to clipboard.

NHBC Standards 2024 - Chapter 8.4.1

3.47 MB (English)
Download

URL for NHBC Standards 2024 - Chapter 8.4.1 copied to clipboard.

How to change MVHR Filters

6.5 MB (English)
Download

URL for How to change MVHR Filters copied to clipboard.

Condensation Drain - User Guide/Installer Guide

244.96 KB (English)
Download

URL for Condensation Drain - User Guide/Installer Guide copied to clipboard.

HRV Q Plus - Port Configurations/Airflow Direction (Vertical Units)

2.43 MB (English)
Download

URL for HRV Q Plus - Port Configurations/Airflow Direction (Vertical Units) copied to clipboard.

HRV Q Plus - User Guide

835.61 KB (English)
Download

URL for HRV Q Plus - User Guide copied to clipboard.

HRV Vertical Mounting Information - User Guide

611.71 KB (English)
Download

URL for HRV Vertical Mounting Information - User Guide copied to clipboard.

Test Results

Product Characteristics Database (PCDB) – HRV4 Q Plus Test Results

(English)
Visit URL

URL for Product Characteristics Database (PCDB) – HRV4 Q Plus Test Results copied to clipboard.

URL

How to identify which HRV (MVHR) you have

(English)
Visit URL

URL for How to identify which HRV (MVHR) you have copied to clipboard.

Quote and Order Form

Request for Information (R.F.I.) Form

129.12 KB (English)
Download

URL for Request for Information (R.F.I.) Form copied to clipboard.

Product Fiches

Videos

Video: How to replace filters in a Titon MVHR unit

(English)
Visit URL

URL for Video: How to replace filters in a Titon MVHR unit copied to clipboard.

CE Certificate of Conformity

HRV4 Q Plus EcoAura Certificate of Conformity (TP431B2-LR-T)

84.65 KB (English)
Download

URL for HRV4 Q Plus EcoAura Certificate of Conformity (TP431B2-LR-T) copied to clipboard.

HRV4 Q Plus EcoAura Certificate of Conformity (TP431B2F-LR-T)

84.65 KB (English)
Download

URL for HRV4 Q Plus EcoAura Certificate of Conformity (TP431B2F-LR-T) copied to clipboard.

HRV4 Q Plus Eco HMB Certificate of Conformity (TP421HMB-RH)

82.25 KB (English)
Download

URL for HRV4 Q Plus Eco HMB Certificate of Conformity (TP421HMB-RH) copied to clipboard.

HRV4 Q Plus Eco HMB Certificate of Conformity (TP421HMB-544)

82.25 KB (English)
Download

URL for HRV4 Q Plus Eco HMB Certificate of Conformity (TP421HMB-544) copied to clipboard.

Similar Products

Similar Products

Contact one of our experts

Whatever your query, please get in touch.