Heat Recovery (MVHR)
Click a product name for full details.
MVHR
Comparison
Chart
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Width
|
600mm
|
600mm
|
600mm
|
715mm
|
715mm
|
715mm
|
715mm
|
790mm
|
800mm
|
790mm
|
800mm
|
752mm
|
600mm
|
Height excl. Ports
|
430mm
|
430mm
|
505mm
|
490mm
|
490mm
|
490mm
|
490mm
|
665mm
|
675mm
|
665mm
|
675mm
|
708mm
|
200mm
|
Depth
|
285mm
|
285mm
|
353mm
|
415mm
|
415mm
|
415mm
|
415mm
|
485mm
|
495mm
|
485mm
|
495mm
|
533mm
|
1000mm
|
Depth incl.
Mounting
Bracket
|
295mm
|
295mm
|
363mm
|
426mm
|
426mm
|
426mm
|
426mm
|
495mm
|
505mm
|
495mm
|
505mm
|
549mm
|
–
|
Housing
|
Zintec Sheet Steel
|
Zintec Sheet Steel
|
Zintec Sheet Steel
|
Zintec Sheet Steel
|
Zintec Sheet Steel
|
Zintec Sheet Steel
|
Zintec Sheet Steel
|
Expanded Poly-
propylene
|
Zintec Sheet Steel
|
Expanded Poly-
propylene
|
Zintec
Sheet
Steel
|
Zintec Sheet Steel
|
Zintec Sheet Steel
|
Weight
|
16kg
|
16kg
|
22kg
|
24kg
|
24kg
|
24.5kg
|
24.5kg
|
17.5kg
|
31kg
|
18kg
|
31.5kg
|
46kg
|
32kg
|
Filters
|
ISO Coarse 60%
(G4) Synthetic Filters
|
ISO Coarse 60%
(G4) Synthetic Filters
|
ISO Coarse 60%
(G4) Synthetic Filters
|
ISO Coarse 60%
(G4) Synthetic Filters
|
ISO Coarse 60%
(G4) Synthetic Filters
|
ISO Coarse 60%
(G4) Synthetic Filters
|
ISO Coarse 60%
(G4) Synthetic Filters
|
ISO Coarse 60%
(G4) Pleated Panel Filters
|
ISO Coarse 60%
(G4) Pleated Panel Filters
|
ISO Coarse 60%
(G4) Pleated Panel Filters
|
ISO
Coarse
60%
(G4)
Pleated
Panel
Filters
|
ISO Coarse 60%
(G4) Pleated Panel Filters
|
ISO Coarse 60%
(G4) Pleated Panel Filters
|
Specific
Fan
Power
(down to)
|
0.53 W/I/s
|
0.65 W/I/s
|
0.49 W/I/s
|
0.48 W/I/s
|
0.54 W/I/s
|
0.67 W/I/s
|
0.40 Wh/m3
|
0.48 W/I/s
|
0.48 W/I/s
|
0.39 W/I/s
|
0.39
W/I/s
|
0.48 W/I/s
|
0.55 W/I/s
|
Heat Recovery
% (up to)
|
89%
|
88%
|
89%
|
89%
|
92%
|
90%
|
90%
|
91%
|
91%
|
90%
|
90%
|
92%
|
83%
|
Airflow (m3/h) at 100Pa
|
158
|
237
|
359
|
274 |
334
|
379
|
379
|
399
|
399
|
518
|
518
|
640
|
300
|
Airflow (l/s) at 100Pa
|
44
|
66
|
100
|
76
|
93
|
105
|
105
|
111
|
111
|
144
|
144
|
178
|
83
|
*Maximum Floor Area (m2) (<5)
|
85
|
115
|
160
|
125
|
145
|
205
|
205
|
200
|
200
|
225
|
225
|
290
|
150
|
100%
Summer Bypass
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
Constant Flow
|
|
|
|
|
|
⚫
|
|
|
|
|
|
|
|
Energy Rating
|
A
|
A
|
A+
|
A+
|
A+
|
A
|
A
|
A+
|
A+
|
A
|
A
|
A
|
A
|
0-10V Connections for B variants
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
Electrical power
|
230V ~ 50/60Hz, 3A fuse
|
230V ~ 50/60Hz, 3A fuse
|
230V ~ 50/60Hz, 3A fuse
|
230V ~ 50/60Hz, 3A fuse
|
230V ~ 50/60Hz, 3A fuse
|
230V ~ 50/60Hz, 5A fuse
|
230V ~ 50/60Hz, 5A fuse
|
230V ~ 50/60Hz, 5A fuse
|
230V ~ 50/60Hz, 5A fuse
|
230V ~ 50/60Hz, 5A fuse
|
230V ~ 50/60Hz, 5A fuse
|
230V ~ 50/60Hz, 5A fuse
|
230V ~ 50/60Hz, 5A fuse
|
Onboard control option (aura-t)
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
|
|
⚫
|
|
⚫
|
⚫
|
|
Duct heater connection
(B Models only)
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
Cold Climate Option
|
|
⚫
|
⚫
|
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
Enthalpy Option
|
|
⚫
|
⚫
|
|
|
⚫
|
|
|
|
⚫
|
|
⚫
|
|
Recommended ducting Ø
|
125mm
|
125mm
|
125mm
|
150mm
|
150mm
|
150mm
|
150mm
|
150mm
|
150mm
|
150mm
|
150mm
|
200mm
|
150mm
|
Available – Left and Right handed
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
⚫
|
|
|
|
|
⚫
|
|
* based on the unit running at 65% capacity assuming typical system resistances and using ducting equal to the spigot diameter. Unit selection will also be dependant on system design.