Skip to content

HRV2.85 Q Plus

Mechanical Ventilation with Heat Recovery unit (MVHR)
MEDIUM TO LARGE SIZED DWELLINGS
Buy

Overview

The enhanced capacity ultra-compact HRV2.85 Q Plus continuously running whole house ventilation unit with heat recovery has been specifically designed to give improved performance over older models, in line with new build design requirements. It is independently tested by the BRE.

Combining extremely low power consumption and a highly efficient heat exchanger, the HRV2.85 Q Plus is specifically designed to enhance SAP performance via Appendix Q, yet still small enough to be easily incorporated into medium or large sized dwellings.

The Eco versions offer a 100% airflow diverting Summer Bypass, recognised and listed in the UK Product Characteristics Database. They also include intelligent humidity options and can be fitted with the auralite® status indicator, aura-t™ controller (HMB or B Models) or the auramode® and aurastat® controllers (B models only).

Features & Benefits

  • Highly compact, making a highly versatile unit
  • Lightweight for easy handling
  • Extremely low Specific Fan Power of 0.52 W/l/s
  • Highly efficient heat exchanger; up to 91%
  • Airflow up to 98 l/s (352 m3/h) at 100 Pa
  • Summer Mode facility as standard
  • Intelligent controller, quick and easy to commission
  • Accepts 125mm or 150mm diameter ducting, no adaptors required
  • Independent fan adjustment
  • Intelligent frost protection, stepped reduction of supply air rates prevents HRV unit from freezing
  • Setback facility to reduce ventilation where local regulations allow
  • Fully adjustable boost overrun timer 0-60 minutes; can be used with non-latching (momentary) switches to prevent unit from being accidently left in boost mode
  • Re-usable plastic filter frames
  • Volt free switching control
  • ISO Coarse 55% (G3) filters as standard (UK only) with ISO Coarse 60% (G4) as an option
  • Quick fix mounting bracket
  • On board aura-tTM capabilities
  • Patented features and design
  • Effective in reducing pollutants in the home and improving Indoor Air Quality (IAQ), therefore reducing the risk of Toxic Home Syndrome.

Basic Version;

  • Summer Mode

Eco Versions;

  • Intelligent Summer Bypass & humidity controls
  • SUMMERboost® facility

Eco HMB Models;

  • Compatible with auralite® status (TP518) indicator and aura-t™ controller
  • Quick access filter doors as standard

Eco B Models;

  • Compatible with aura range; aurastat®, auramode®, aura-t™ and auralite® (TP519) controllers
  • Duct heater control (requires independent power supply)
  • Available in left and right handed configurations
  • BMS compatible via RS485

Compatible Products

aurastat® V & VT

For use with Titon HRV Q Plus Range gives enhanced commissioning capabilities

Technical Information

Technical Information

Technical Information

Exhaust terminal configuration*
Fan speed setting
Specific fan power (W/l/s)
Heat exchange efficiency (%)
Kitchen + 1 additional wet room
100% variable
0.56
91
Kitchen + 2 additional wet room
100% variable
0.52
90
Kitchen + 3 additional wet room
100% variable
0.53
90
Kitchen + 4 additional wet room
100% variable
0.62
89
Kitchen + 5 additional wet room
100% variable
0.71
88
Kitchen + 6 additional wet room
100% variable
0.83
88
Kitchen + 7 additional wet room
100% variable
0.97
87

Figures taken from the BRE Test Results.
*Number of wet rooms is based on SAP Q test criteria and does not correlate directly with regulatory performance requirements.

Performance Curve

*@FID (0 Pa)
All units offer 100% variable speed control.

Acoustic Data

Product
% of Max flow
Airflow
dB(A) @ 3m Hemispherical
dB(A) @ 3m Spherical
Induct Inlet
Induct Outlet
Casing Breakout
Casing Breakout
HRV2.85
Q Plus Eco
31%
29l/s @ 7Pa
22
33
14
11
66%
61l/s @ 40Pa
34
47
24
21
100%
93l/s @ 100Pa
42
56
34
31

All acoustic data is third party tested at Sound Research Laboratories (SRL) Ltd.

Product Codes

HRV2.85 Q PlusTP407A – Energy Rating A.
HRV2.85 Q Plus HMB Eco auralite® and aura-tTM ready – TP407HMB – Energy Rating A.
HRV2.85 Q Plus B Eco-aura controls ready – TP417B/LH (left hand config) or TP417B/RH (right hand config) – Energy Rating A+.
HRV2.85 Q Plus B Eco-aura controls ready – TP417BC – Energy Rating A+.

Filters:
XP40132/099 – ISO Coarse 55% (G3) filters fitted as standard (UK only).
XP46122/099 – ISO Coarse 60% (G4) filters fitted on request (Europe fitted as standard).

Filters (Eco Versions):
XP40133/099 – ISO Coarse 55% (G3) filters fitted as standard (UK only).
XP46133/099 – ISO Coarse 60% (G4) filters fitted on request (Europe fitted as standard).
XP46222/099 – ISO Coarse 55% (G3)/ISO ePM1 55% (F7) filters available on request.
XP46232/099 – ISO Coarse 60% (G4) filters/ISO ePM1 55% (F7) filters available on request.

Standards

Conforms to requirements of UK statutory Building Regulations and Technical Standards for Ventilation and BRE 398.
SAP Appendix Q tested
Exceeds requirements of Building Regulations Approved Document L (England & Wales).
EU RoHS Directive compliant.
Conforms to requirements of EC council directives relating to Electromagnetic Compatibility and Electrical Safety:
2006/95/EC (LVD), 2004/108/EC (EMC), EN 60335-1:2002/A2:2006, EN 60335-2- 80:2003/A1:2004.
CE Marked.

Specification

Dimensions: 715mm wide x 490mm high (excluding ports) x 415mm deep (426mm with mounting bracket).
Weight: 24kg.
Finish: White Paint.

Materials:
Housing: Zintec sheet steel housing, powder coated white.
Internals: Expanded polypropylene (EPP).
Heat exchanger: Polystyrene.
Internal insulation: Closed cell foamed Nitrile rubber, class ‘O’ fire rating.
Standard filters: Grade ISO Coarse 55% (G3) synthetic filters.
Guarantee period: 3 years (UK only).
Electrical: 230V ~ 50/60Hz, 3A fuse.
Installation: Install in accordance with regulatory requirements, such as the Domestic Ventilation Compliance Guide (England & Wales) and the Residential Ventilation Association recommendations.
Maintenance: Service and filter clean/replacement subject to local environment – see product manual.
AcousticsFull acoustic data.

Documentation

Resources

Manuals and Documentation

Product Manual - auramode Constant Flow Unit Controller BAR units

8.38 MB (English)
Download

URL for Product Manual - auramode Constant Flow Unit Controller BAR units copied to clipboard.

Product Manual - auralite® (TP519)

340.24 KB (English)
Download

URL for Product Manual - auralite® (TP519) copied to clipboard.

Product Manual - aura-t™ HMB Model

3.83 MB (English)
Download

URL for Product Manual - aura-t™ HMB Model copied to clipboard.

Product Manual - aura-t™ B Model GBR

4.95 MB (English)
Download

URL for Product Manual - aura-t™ B Model GBR copied to clipboard.

Product Manual - Boxed Relay 5A (TP505)

575.63 KB (English)
Download

URL for Product Manual - Boxed Relay 5A (TP505) copied to clipboard.

Manuals and Documentation (Obsolete)

Test Results

Product Characteristics Database (PCDB) – HRV2.85 Q Plus ECO Test Results

(English)
Visit URL

URL for Product Characteristics Database (PCDB) – HRV2.85 Q Plus ECO Test Results copied to clipboard.

Specifier Text

HRV2.85 Q Plus - Specifiers Text (TP407B)

198.66 KB (English)
Download

URL for HRV2.85 Q Plus - Specifiers Text (TP407B) copied to clipboard.

HRV2.85 Q Plus - Specifiers Text (TP407HMB)

197.12 KB (English)
Download

URL for HRV2.85 Q Plus - Specifiers Text (TP407HMB) copied to clipboard.

HRV2.85 Q Plus - Specifiers Text (TP407A)

196.61 KB (English)
Download

URL for HRV2.85 Q Plus - Specifiers Text (TP407A) copied to clipboard.

Catalogues

HRV2.85 Q Plus - Catalogue Page

582.41 KB (English)
Download

URL for HRV2.85 Q Plus - Catalogue Page copied to clipboard.

HRV - Sales Brochure

1.58 MB (English)
Download

URL for HRV - Sales Brochure copied to clipboard.

aura-t™ B – Catalogue Page

264.57 KB (English)
Download

URL for aura-t™ B – Catalogue Page copied to clipboard.

aura-t™ HMB - Catalogue Page

263.78 KB (English)
Download

URL for aura-t™ HMB - Catalogue Page copied to clipboard.

aurastat® - Catalogue Page

312.76 KB (English)
Download

URL for aurastat® - Catalogue Page copied to clipboard.

auralite® - Catalogue Page

269.01 KB (English)
Download

URL for auralite® - Catalogue Page copied to clipboard.

auramode® - Catalogue Page

329.73 KB (English)
Download

URL for auramode® - Catalogue Page copied to clipboard.

MVHR/HRV Drain Conversion - Datasheet

334.56 KB (English)
Download

URL for MVHR/HRV Drain Conversion - Datasheet copied to clipboard.

Acoustic Information

HRV2.85 Q Plus - Acoustic Results

558.5 KB (English)
Download

URL for HRV2.85 Q Plus - Acoustic Results copied to clipboard.

Sound Attenuating Ventilation

385.72 KB (English)
Download

URL for Sound Attenuating Ventilation copied to clipboard.

Certificate of Conformity

HRV2.85 Q Plus - Certificate of Conformity (TP417B-SVN-RH)

1.02 MB (English)
Download

URL for HRV2.85 Q Plus - Certificate of Conformity (TP417B-SVN-RH) copied to clipboard.

HRV2.85 Q Plus - Certificate of Conformity (TP417B-SVN-LH)

1.02 MB (English)
Download

URL for HRV2.85 Q Plus - Certificate of Conformity (TP417B-SVN-LH) copied to clipboard.

HRV2.85 Q Plus - Certificate of Conformity (TP417B-ROU-RH)

1.02 MB (English)
Download

URL for HRV2.85 Q Plus - Certificate of Conformity (TP417B-ROU-RH) copied to clipboard.

HRV2.85 Q Plus - Certificate of Conformity (TP417B-ROU-LH)

1.02 MB (English)
Download

URL for HRV2.85 Q Plus - Certificate of Conformity (TP417B-ROU-LH) copied to clipboard.

HRV2.85 Q Plus - Certificate of Conformity (TP417B-RH)

1.02 MB (English)
Download

URL for HRV2.85 Q Plus - Certificate of Conformity (TP417B-RH) copied to clipboard.

HRV2.85 Q Plus - Certificate of Conformity (TP417B-LTU-LH)

1.02 MB (English)
Download

URL for HRV2.85 Q Plus - Certificate of Conformity (TP417B-LTU-LH) copied to clipboard.

HRV2.85 Q Plus - Certificate of Conformity (TP417B-LH)

1.02 MB (English)
Download

URL for HRV2.85 Q Plus - Certificate of Conformity (TP417B-LH) copied to clipboard.

HRV2.85 Q Plus - Certificate of Conformity (TP417BC-LTU-RH)

1.02 MB (English)
Download

URL for HRV2.85 Q Plus - Certificate of Conformity (TP417BC-LTU-RH) copied to clipboard.

HRV2.85 Q Plus - Certificate of Conformity (TP417BC-LTU-LH)

1.02 MB (English)
Download

URL for HRV2.85 Q Plus - Certificate of Conformity (TP417BC-LTU-LH) copied to clipboard.

HRV2.85 Q Plus - Certificate of Conformity (TP417BC-LH)

1.02 MB (English)
Download

URL for HRV2.85 Q Plus - Certificate of Conformity (TP417BC-LH) copied to clipboard.

HRV2.85 Q Plus - Certificate of Conformity (TP417BC-EST-RH)

1.02 MB (English)
Download

URL for HRV2.85 Q Plus - Certificate of Conformity (TP417BC-EST-RH) copied to clipboard.

HRV2.85 Q Plus - Certificate of Conformity (TP417BC-EST-LH)

1.02 MB (English)
Download

URL for HRV2.85 Q Plus - Certificate of Conformity (TP417BC-EST-LH) copied to clipboard.

HRV2.85 Q Plus - Certificate of Conformity (TP417B-BEL-RH)

1.02 MB (English)
Download

URL for HRV2.85 Q Plus - Certificate of Conformity (TP417B-BEL-RH) copied to clipboard.

HRV2.85 Q Plus - Certificate of Conformity (TP417B-BEL-LH)

1.02 MB (English)
Download

URL for HRV2.85 Q Plus - Certificate of Conformity (TP417B-BEL-LH) copied to clipboard.

HRV2.85 Q Plus - Certificate of Conformity (TP407HMB-RH)

351.21 KB (English)
Download

URL for HRV2.85 Q Plus - Certificate of Conformity (TP407HMB-RH) copied to clipboard.

HRV1.75 Q Plus - Certificate of Conformity (TP407HMB-544-F)

424.43 KB (English)
Download

URL for HRV1.75 Q Plus - Certificate of Conformity (TP407HMB-544-F) copied to clipboard.

HRV1.75 Q Plus - Certificate of Conformity (TP407HMB-544)

351.21 KB (English)
Download

URL for HRV1.75 Q Plus - Certificate of Conformity (TP407HMB-544) copied to clipboard.

HRV1.75 Q Plus - Certificate of Conformity (TP407A-544F)

351.2 KB (English)
Download

URL for HRV1.75 Q Plus - Certificate of Conformity (TP407A-544F) copied to clipboard.

HRV1.75 Q Plus - Certificate of Conformity (TP407A-544)

1.02 MB (English)
Download

URL for HRV1.75 Q Plus - Certificate of Conformity (TP407A-544) copied to clipboard.

User Guides

HRV - Spares Matrix

901.89 KB (English)
Download

URL for HRV - Spares Matrix copied to clipboard.

HRV Q Plus - Fault Finding (MB)

1.94 MB (English)
Download

URL for HRV Q Plus - Fault Finding (MB) copied to clipboard.

HRV Q Plus - Fault Finding (ABS)

1.74 MB (English)
Download

URL for HRV Q Plus - Fault Finding (ABS) copied to clipboard.

HRV Q Plus - Fault Finding (A)

934.79 KB (English)
Download

URL for HRV Q Plus - Fault Finding (A) copied to clipboard.

HRV Q Plus - Fault Finding (ABD)

1.63 MB (English)
Download

URL for HRV Q Plus - Fault Finding (ABD) copied to clipboard.

HRV Q Plus - Fault Finding (HMB)

2.08 MB (English)
Download

URL for HRV Q Plus - Fault Finding (HMB) copied to clipboard.

HRV Q Plus - Port Configurations (Vertical Units)

2.19 MB (English)
Download

URL for HRV Q Plus - Port Configurations (Vertical Units) copied to clipboard.

HRV Q Plus - User Guide

835.61 KB (English)
Download

URL for HRV Q Plus - User Guide copied to clipboard.

aurastat® - Defaults Guide

147.38 KB (English)
Download

URL for aurastat® - Defaults Guide copied to clipboard.

Product Fiches

BIM Models

MVHR Vertical (RH) - BIM Model

451.37 KB (English)
Download

URL for MVHR Vertical (RH) - BIM Model copied to clipboard.

MVHR Vertical (LH) - BIM Model

454.45 KB (English)
Download

URL for MVHR Vertical (LH) - BIM Model copied to clipboard.

Videos

Video - How to change a filter (HRV)

(English)
Visit URL

URL for Video - How to change a filter (HRV) copied to clipboard.

Similar Products

Similar Products

Woman working at computer

Contact one of our experts

Whatever your query, please get in touch.