HRV10M Q Plus (Obsolete)

Mechanical Ventilation with Heat Recovery unit (MVHR)
LARGE SIZED DWELLINGS

Overview

The HRV10M Q Plus continuously running whole house ventilation unit with heat recovery has been specifically designed to give improved performance over older models, in line with new build design requirements.

Combining of extremely low power consumption and a highly efficient heat exchanger specifically designed to enhance SAP performance via Appendix Q and can be incorporated into larger apartments or dwellings.

The HRV10M Q Plus Range of MVHR unit comes in three different models; our ‘A’ model which is our basic version and our ‘HMB’ & ‘B’ models which are part of our Eco version range.  Each set out to accommodate our customers’ needs.

Recognised and listed in the UK Product Characteristics Database and includes intelligent humidity options through controller options.

Looking for after sales support?

Features & Benefits

  • Extremely low Specific Fan Power; down to 0.52 W/l/s
  • Highly efficient heat exchanger; up to 91%
  • Airflow up to 111 l/s (399 m3/h) at 100 Pa
  • Lightweight EPP construction giving high levels of thermal insulation
  • Accepts 150mm diameter ducting
  • Independent fan adjustment
  • Intelligent frost protection, stepped reduction of supply air rates prevents HRV unit from freezing
  • Setback facility to reduce ventilation where local regulations allow
  • Fully adjustable boost overrun timer 0-60 minutes; can be used with non-latching (momentary) switches to prevent unit from being accidentally left in boost mode
  • EPP moulded 150mm low resistance insulated port adaptors included as standard
  • EPP version lightweight for easy handling
  • Volt free switching control
  • Pleated ISO Coarse 65% (G4) filters as standard. ISO ePM1 55% (F7) on request (Standard unit only)
  • Available in Zintec sheet steel casing or EPP
  • Quick fix mounting bracket
  • IP32 rating
  • Patented features
  • Effective in reducing pollutants in the home and improving Indoor Air Quality (IAQ), therefore reducing the risk of Toxic Home Syndrome

Technical Information

Technical Information

Product Codes and Specific Features

Basic version;

  • Summer Mode
Product Model Product Code Energy Rating
HRV10M Q Plus TP441A Energy Rating A

Eco versions;

Eco HMB Models;

  • Intelligent Summer Bypass & humidity controls
  • SUMMERboost® facility
  • Compatible with auralite® HRV (TP518) status indicator and aura-t™ (TP539) controller
  • Intelligent controller, quick and easy to commission
Product Model Product Code Energy Rating
HRV10M Q Plus HMB
Eco auralite® & aura-tTM ready
TP441HMB Energy Rating A

Eco B Models;

  • Intelligent Summer Bypass & humidity controls
  • SUMMERboost® facility
  • Compatible with Eco-aura range; aurastat®, auramode® and aura-t™ (TP536) controllers and auralite® HRV (TP519) status indicator
  • Intelligent controller, quick and easy to commission
  • Duct Pre-heater control (requires independent power supply)
  • BMS compatible via RS485 (subject to limitations, additional software requirements and specification with any order)
  • Cold Climate option available
Product Model Product Code Energy Rating
HRV10M Q Plus B
Eco-aura controls ready
TP481B Energy Rating A+
HRV10M Q Plus B
Eco-aura controls Cold Climate ready
TP481BC Energy Rating A+

Filters:
XP44022/099 – ISO Coarse 65% (G4) filter set fitted as standard.

Filters (Eco versions):
XP44023/099 – ISO Coarse 65% (G4) bypass filter set fitted as standard.
XP46223/099 – ISO Coarse 65% (G4)/ISO ePM1 55% (F7) filters available on request.

Standards

Conforms to requirements of UK statutory Building Regulations and Technical Standards for Ventilation and BRE 398.
SAP Appendix Q tested
Exceeds requirements of Building Regulations Approved Document L (England & Wales).
EU RoHS Directive compliant.
Conforms to requirements of EC council directives relating to Electromagnetic Compatibility and Electrical Safety:
2006/95/EC (LVD), 2004/108/EC (EMC), EN 60335-1:2002/A2:2006, EN 60335-2- 80:2003/A1:2004.
CE and UKCA Marked.

Specification

Dimensions: 800mm wide x 675mm high (excluding ports) x 470mm deep (481mm with mounting bracket).


Weight: 37kg.
Finish: White Paint (RAL9016 Semi-gloss Traffic White).

Materials
Housing
: Zintec sheet steel housing, powder coated white
Internals: Expanded polypropylene (EPP)
Heat exchanger: Polystyrene
Internal insulation: Closed cell foamed Nitrile rubber, class ‘O’ fire rating
Standard filters: Grade ISO Coarse 65% (G4) pleated panel filters.

Guarantee period: 3 years (UK only).
Electrical: 230V ~ 50/60Hz, 3A fuse.
Installation: To be installed accordance with the relevant and applicable building regulations.
Maintenance: Service and filter replacement subject to local environment – see product manual.
AcousticsFull acoustic data.

Performance

Exhaust terminal configuration*
Fan speed setting
Specific fan power (W/l/s)
Heat exchange efficiency (%)
Specific fan power (W/l/s)
Heat exchange efficiency (%)
2009
2012
Kitchen + 1 additional wet room
100% variable
0.57
91%
0.55
90%
Kitchen + 2 additional wet room
100% variable
0.52
90%
0.57
90%
Kitchen + 3 additional wet room
100% variable
0.53
90%
0.65
89%
Kitchen + 4 additional wet room
100% variable
0.59
89%
0.76
88%
Kitchen + 5 additional wet room
100% variable
0.65
89%
0.9
87%
Kitchen + 6 additional wet room
100% variable
0.74
88%
1.09
86%
Kitchen + 7 additional wet room
100% variable
0.88
87%
1.27
85%

Figures taken from the BRE Test Results.
*Number of wet rooms is based on SAP Q test criteria and does not correlate directly with regulatory performance requirements.

Performance Curve

*@FID (0 Pa)
All units offer 100% variable speed control

Acoustic Data

Product
% of Max flow
Airflow
dB(A) @ 3m Hemispherical
dB(A) @ 3m Spherical
Induct
Inlet
Induct Outlet
Casing Breakout
Casing Breakout
HRV10M Q Plus Eco
41%
44l/s @ 22Pa
27
38
27
20
69%
75l/s @ 51Pa
36
48
37
30
100%
108l/s @ 100Pa
43
57
51
43

For full frequency acoustic data at various speeds please see www.titon.co.uk. All acoustic data is third party tested at Sound Research Laboratories (SRL) Ltd.

Documentation

Resources

Manuals and Documentation

Product Manual - auralite® HRV (TP519)

340.24 KB (English)
Download

URL for Product Manual - auralite® HRV (TP519) copied to clipboard.

Product Manual - aura-t™ HMB Model

3.83 MB (English)
Download

URL for Product Manual - aura-t™ HMB Model copied to clipboard.

Product Manual - aura-t™ B Model GBR

4.95 MB (English)
Download

URL for Product Manual - aura-t™ B Model GBR copied to clipboard.

Product Manual - auramode Constant Flow Unit Controller BAR units

8.38 MB (English)
Download

URL for Product Manual - auramode Constant Flow Unit Controller BAR units copied to clipboard.

HRV AV Mounting Kits - Fitting Instruction

731.35 KB (English)
Download

URL for HRV AV Mounting Kits - Fitting Instruction copied to clipboard.

Product Manual - Boxed Relay 5A (TP505)

575.63 KB (English)
Download

URL for Product Manual - Boxed Relay 5A (TP505) copied to clipboard.

MVHR/HRV Drain Conversion - Datasheet

334.56 KB (English)
Download

URL for MVHR/HRV Drain Conversion - Datasheet copied to clipboard.

Catalogues

Ventilation Systems Catalogue

19.35 MB (English)
Download

URL for Ventilation Systems Catalogue copied to clipboard.

Ventilation Product Overview Brochure

3.81 MB (English)
Download

URL for Ventilation Product Overview Brochure copied to clipboard.

MVHR - Overview Brochure (Export Version)

1.34 MB (English)
Download

URL for MVHR - Overview Brochure (Export Version) copied to clipboard.

Case Studies

Case Study: HRV10 Q Plus units / Trimbox NO2 Filter® units, London

(English)
Visit URL

URL for Case Study: HRV10 Q Plus units / Trimbox NO2 Filter® units, London copied to clipboard.

Specifier Text

HRV10M Q Plus - Specifiers Text (TP441A)

196.61 KB (English)
Download

URL for HRV10M Q Plus - Specifiers Text (TP441A) copied to clipboard.

HRV10M Q Plus - Specifiers Text (TP441HMB)

198.14 KB (English)
Download

URL for HRV10M Q Plus - Specifiers Text (TP441HMB) copied to clipboard.

HRV10M Q Plus - Specifiers Text (TP481B)

199.17 KB (English)
Download

URL for HRV10M Q Plus - Specifiers Text (TP481B) copied to clipboard.

Acoustic Information

HRV10M Q Plus - Acoustic Performance

559.05 KB (English)
Download

URL for HRV10M Q Plus - Acoustic Performance copied to clipboard.

Sound Attenuating Ventilation

385.72 KB (English)
Download

URL for Sound Attenuating Ventilation copied to clipboard.

User Guides

What is MVHR?

(English)
Visit URL

URL for What is MVHR? copied to clipboard.

Top 10 Install Problems - Guide

2.65 MB (English)
Download

URL for Top 10 Install Problems - Guide copied to clipboard.

NHBC Standards 2024 - Chapter 8.4.1

3.47 MB (English)
Download

URL for NHBC Standards 2024 - Chapter 8.4.1 copied to clipboard.

How to change MVHR Filters

6.5 MB (English)
Download

URL for How to change MVHR Filters copied to clipboard.

Condensation Drain - User Guide/Installer Guide

244.96 KB (English)
Download

URL for Condensation Drain - User Guide/Installer Guide copied to clipboard.

MVHR/MEV Running Costs

165.87 KB (English)
Download

URL for MVHR/MEV Running Costs copied to clipboard.

HRV - Spares Matrix

958.34 KB (English)
Download

URL for HRV - Spares Matrix copied to clipboard.

HRV Q Plus - Port Configurations/Airflow Direction (Vertical Units)

2.43 MB (English)
Download

URL for HRV Q Plus - Port Configurations/Airflow Direction (Vertical Units) copied to clipboard.

HRV Q Plus - User Guide

835.61 KB (English)
Download

URL for HRV Q Plus - User Guide copied to clipboard.

aurastat® - Defaults Guide

147.38 KB (English)
Download

URL for aurastat® - Defaults Guide copied to clipboard.

aura-t™ - Changing from integral to remote

1.18 MB (English)
Download

URL for aura-t™ - Changing from integral to remote copied to clipboard.

Fitting Instructions - HMB aura-t Upgrade Kit

1.06 MB (English)
Download

URL for Fitting Instructions - HMB aura-t Upgrade Kit copied to clipboard.

Connecting a controller to a MVHR Unit - User Guide

129.89 KB (English)
Download

URL for Connecting a controller to a MVHR Unit - User Guide copied to clipboard.

HRV Vertical Mounting Information - User Guide

611.71 KB (English)
Download

URL for HRV Vertical Mounting Information - User Guide copied to clipboard.

aura-t™ - Commissioning Procedure (HMB & B Models)

3.37 MB (English)
Download

URL for aura-t™ - Commissioning Procedure (HMB & B Models) copied to clipboard.

Fault Finding

HRV Q Plus - Fault Finding (HMB) post 1/1/2019

4.16 MB (English)
Download

URL for HRV Q Plus - Fault Finding (HMB) post 1/1/2019 copied to clipboard.

HRV Q Plus – Fault Finding (HMB pre 1/1/2019)

3.22 MB (English)
Download

URL for HRV Q Plus – Fault Finding (HMB pre 1/1/2019) copied to clipboard.

HRV Q Plus - Fault Finding (B Models)

1.77 MB (English)
Download

URL for HRV Q Plus - Fault Finding (B Models) copied to clipboard.

HRV Q Plus - Fault Finding (MB)

2.96 MB (English)
Download

URL for HRV Q Plus - Fault Finding (MB) copied to clipboard.

HRV Q Plus - Fault Finding (ABS)

2.25 MB (English)
Download

URL for HRV Q Plus - Fault Finding (ABS) copied to clipboard.

HRV Q Plus - Fault Finding (ABD)

2.28 MB (English)
Download

URL for HRV Q Plus - Fault Finding (ABD) copied to clipboard.

HRV Q Plus - Fault Finding (A)

1.62 MB (English)
Download

URL for HRV Q Plus - Fault Finding (A) copied to clipboard.

Calculators

Part F Calculator (UK only)

30.75 KB (English)
Download

URL for Part F Calculator (UK only) copied to clipboard.

Test Results

Product Characteristics Database (PCDB) – HRV10 Q Plus ECO Test Results

(English)
Visit URL

URL for Product Characteristics Database (PCDB) – HRV10 Q Plus ECO Test Results copied to clipboard.

URL

How to identify which HRV (MVHR) you have

(English)
Visit URL

URL for How to identify which HRV (MVHR) you have copied to clipboard.

The CPD Certification Service

(English)
Visit URL

URL for The CPD Certification Service copied to clipboard.

Manuals and Documentation (Obsolete)

Product Manual - HRV10 & 10M Q Plus (TP440A, TP440ABD, TP440ABS, TP441A , TP441ABD, TP441ABS) - (Obsolete)

5.06 MB (English)
Download

URL for Product Manual - HRV10 & 10M Q Plus (TP440A, TP440ABD, TP440ABS, TP441A , TP441ABD, TP441ABS) - (Obsolete) copied to clipboard.

Product Manual - HRV10 & 10M Q Plus (TP480B & TP481B) - (Obsolete)

2.59 MB (Français)
Download

URL for Product Manual - HRV10 & 10M Q Plus (TP480B & TP481B) - (Obsolete) copied to clipboard.

Product Manual - HRV10 & 10M Q Plus (TP440MB & TP441MB) - (Obsolete)

3.25 MB (English)
Download

URL for Product Manual - HRV10 & 10M Q Plus (TP440MB & TP441MB) - (Obsolete) copied to clipboard.

Product Manual - HRV10 & 10M Q Plus (TP440HMB & TP441HMB) - (Obsolete)

2.65 MB (English)
Download

URL for Product Manual - HRV10 & 10M Q Plus (TP440HMB & TP441HMB) - (Obsolete) copied to clipboard.

Catalogues (Obsolete)

HRV10 Q Plus - Catalogue Page (Obsolete)

867.7 KB (English)
Download

URL for HRV10 Q Plus - Catalogue Page (Obsolete) copied to clipboard.

Quote and Order Form

Request for Information (R.F.I.) Form

129.12 KB (English)
Download

URL for Request for Information (R.F.I.) Form copied to clipboard.

Product Fiches

BIM Models

MVHR Vertical - BIM Model

1.79 MB (English)
Download

URL for MVHR Vertical - BIM Model copied to clipboard.

Videos

Video: How to replace filters in a Titon MVHR unit

(English)
Visit URL

URL for Video: How to replace filters in a Titon MVHR unit copied to clipboard.

Video: Mechanical Ventilation with Heat Recovery - Part F: System 4 Loft

(English)
Visit URL

URL for Video: Mechanical Ventilation with Heat Recovery - Part F: System 4 Loft copied to clipboard.

Video: MVHR - How it Works: Summer Bypass

(English)
Visit URL

URL for Video: MVHR - How it Works: Summer Bypass copied to clipboard.

Video: MVHR - How it Works: Summer Mode

(English)
Visit URL

URL for Video: MVHR - How it Works: Summer Mode copied to clipboard.

Video: MVHR - How it Works: SUMMERboost®

(English)
Visit URL

URL for Video: MVHR - How it Works: SUMMERboost® copied to clipboard.

Video: MVHR - How it Works: Boost Speed with Overrun Timer

(English)
Visit URL

URL for Video: MVHR - How it Works: Boost Speed with Overrun Timer copied to clipboard.

Video: MVHR - How it Works: Setback Speed

(English)
Visit URL

URL for Video: MVHR - How it Works: Setback Speed copied to clipboard.

Video: Mechanical Ventilation with Heat Recovery - Part F: System 4

(English)
Visit URL

URL for Video: Mechanical Ventilation with Heat Recovery - Part F: System 4 copied to clipboard.

Video: Product Overview - HRV 10, 10M, 10.25 & 10.25M (Vertical MVHR)

(English)
Visit URL

URL for Video: Product Overview - HRV 10, 10M, 10.25 & 10.25M (Vertical MVHR) copied to clipboard.

Video: MVHR Unit - Motor Replacement Guide: HRV10, 10M, 10.25 and 10.25M

(English)
Visit URL

URL for Video: MVHR Unit - Motor Replacement Guide: HRV10, 10M, 10.25 and 10.25M copied to clipboard.

CE Certificate of Conformity

HRV10M Q Plus - Certificate of Conformity (TP481B-SVN)

371.12 KB (English)
Download

URL for HRV10M Q Plus - Certificate of Conformity (TP481B-SVN) copied to clipboard.

HRV10M Q Plus - Certificate of Conformity (TP481B-544)

371.12 KB (English)
Download

URL for HRV10M Q Plus - Certificate of Conformity (TP481B-544) copied to clipboard.

HRV10M Q Plus - Certificate of Conformity (TP441HMB-BEL)

371.12 KB (English)
Download

URL for HRV10M Q Plus - Certificate of Conformity (TP441HMB-BEL) copied to clipboard.

HRV10M Q Plus - Certificate of Conformity (TP441HMB-544-T)

161.18 KB (English)
Download

URL for HRV10M Q Plus - Certificate of Conformity (TP441HMB-544-T) copied to clipboard.

HRV10M Q Plus - Certificate of Conformity (TP441HMB-544)

371.11 KB (English)
Download

URL for HRV10M Q Plus - Certificate of Conformity (TP441HMB-544) copied to clipboard.

HRV10M Q Plus - Certificate of Conformity (TP441A-544)

305.32 KB (English)
Download

URL for HRV10M Q Plus - Certificate of Conformity (TP441A-544) copied to clipboard.

HVR10M Q Plus – Certificate of Conformity (TP441A)

305.32 KB (English)
Download

URL for HVR10M Q Plus – Certificate of Conformity (TP441A) copied to clipboard.

UKCA Certificate of Conformity

HRV10M Q Plus EcoAura - UKCA Certificate of Conformity (TP481B-544)

372.44 KB (English)
Download

URL for HRV10M Q Plus EcoAura - UKCA Certificate of Conformity (TP481B-544) copied to clipboard.

HRV10M Q Plus Eco HMB - UKCA Certificate of Conformity (TP441HMB-544-T)

164.71 KB (English)
Download

URL for HRV10M Q Plus Eco HMB - UKCA Certificate of Conformity (TP441HMB-544-T) copied to clipboard.

HRV10M Q Plus Eco HMB - UKCA Certificate of Conformity (TP441HMB-544)

372.44 KB (English)
Download

URL for HRV10M Q Plus Eco HMB - UKCA Certificate of Conformity (TP441HMB-544) copied to clipboard.

Similar Products

Similar Products

Contact one of our experts

Whatever your query, please get in touch.